Product details
Model Number: ALR 6~10KVA RT
Brand Name: AWP
Key Specifications/Special Features:
Features:Rack/tower designHigh frequency and true double-conversionDSP digital control technologyInput power factor correction (PFC)Wide input voltage range (110-300 V)
Output power factor 0.9
Cold start
Auto sensing frequency
Eco-friendly mode operation for energy-saving
Selectable output voltage via LCD
50/60Hz frequency conversion mode
Selectable battery low voltage via LCD
Power-on self test
Advanced battery management (ABM)
Short circuit and overload protection
Automatic charging in off mode
Fan speed auto control when temperature varies
Standard RS232 communication port and RJ45 protection
Optional USB/SNMP communication port
Optional emergency power off (EPO)
Optional extension battery bank
Optional N + X redundancy parallel
Model | ALR 6000 | ALR 10000 | |||
Capacity | 6kVA/5400 W | 10kVA/9000 W | |||
Input | |||||
Rated voltage | 208/220/230/240V AC | ||||
Voltage range | (115-295) ± 5V AC (linear derating between 50% and 100% load) full load (160-295) ± 5V AC |
||||
Frequency | 40-70Hz ± 0.5 (auto-sense) | ||||
Power factor | ≥ 0.99 | ||||
Bypass voltage range | rated output voltage*73%- rated output voltage*115% | ||||
Output | |||||
Voltage | 208/220/230/240V AC (settable via LCD) | ||||
Voltage regulation | ± 1% | ||||
Frequency | synchronized with utility in mains mode 50/60Hz ± 0.2Hz in battery mode |
||||
Waveform | sinusoidal | ||||
Crest factor | 3:1 | ||||
Harmonic distortion | ≤ 2% (linear load) ≤ 5% (non-linear load) |
||||
Transfer time | mains mode to battery mode: 0 minute Inverter mode to bypass mode: 0 minute |
||||
Overload | 105-125% for 3 minutes 125-150% for 30 seconds >150% for 0.5 seconds |
||||
Efficiency | |||||
Mains mode | ≥ 92% | ||||
Battery mode | ≥ 91% | ||||
Eco-friendly mode | ≥ 98% | ||||
Batteries | |||||
DC voltage | 192V | ||||
Inbuilt battery of standard model | 12V/7.0Ah x 16 | 12V/9.0Ah x 16 | |||
Charging current | standard model | 1A | |||
Longtime model | 1/ 3/5/8A | ||||
Recharge time | 8H | ||||
Alarms | |||||
Utility failure | 4 seconds per beep | ||||
Low battery | 1 second per beep | ||||
Overload | 1 second twice beep | ||||
UPS fault | Long beep | ||||
Communications | |||||
RS232 (standard) USB (optional) |
supports Windows 98/2000/2003/XP/Vista/2008/7/8/10 | ||||
SNMP (optional) | power management from SNMP manager and web browser | ||||
Others | |||||
Humidity | 20-90% RH at 0-40℃ (non-condensing) | ||||
Noise level | ≤ 55dB (1m) | ||||
Extensible model | dimensions | (W) 440 x (D) 555 x (H) 132mm | |||
packing dimensions | (W) 535 x (D) 660 x (H) 215mm | ||||
weight | net weight: 16.4 gross weight: 20.7kg |
net weight: 17.1kg gross weight: 21.4kg |
|||
Standard model | dimensions | (W) 440 x (D) 580 x (H) 132mm (UPS) (W) 440 x (D) 580 x (H) 132mm (BAT) |
|||
Packing dimensions | (W) 535x (D) 660 x (H) 215mm (UPS) (W) 540 x (D) 685x (H) 235mm (bat) |
||||
Weight | UPS: net weight: 16.4kg Gross weight: 20.7kg BAT: net weight 43.6kg gross weight: 47.1kg |
UPS : NET weight: 17.1kg gross weight: 21.4kg BAT: net weight: 21.4kg 49.6 gross weight: 53.1kg |
Shipping Information:
- FOB Port: Shenzhen
- Lead Time: 15 - 30 days
Main Export Markets:
- Asia
- Australasia
- Central/South America
- Eastern Europe
- Mid East/Africa
- North America
- Western Europe